Van-air-systems E102 Elements User Manual

Browse online or download User Manual for Equipment Van-air-systems E102 Elements. Van Air Systems E102 Elements User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
PRINTED IN THE USA © 2000 VAN AIR SYSTEMS INC. 2950 MECHANIC STREET, LAKE CITY, PA 16423 PAGE 1
FILTER
MODEL
F101-500
F101-1000
F101-1500
F101-2000
F101-3500
F101-5000
BOTTOM
BLIND FLANGE WEIGHT
(LBS.)
28
47
69
69
102
177
To reduce energy consumption from excessive pressure drop and minimize chance of contaminant carryover, install new elements
before pressure drop reaches 10 psid (except grade RD). Install new RD elements when hydrocarbon vapors are first detected
downstream or every six months, whichever comes first.
FIGURE 1 LONG FLANGE BOLT (F101-500 thru 2000)
BEFORE INSTALLING NEW ELEMENT(S), READ INSTRUCTION MANUAL CAREFULLY. NOTE SERIES OF FILTER HOUSING
(F101, F102 OR FHP) AND CONSULT THE APPROPRIATE SECTION FOR SPECIFIC INSTRUCTIONS.
WARNINGS
F101 SERIES
Close inlet and outlet shut-off valves (and open by-pass valve
if provided); or lock out compressed air supply to filter housing.
1.
APRIL 2000
P/N: 432-00128
INSTALLATION INSTRUCTIONS
E101/102 SERIES FILTER ELEMENTS
(FOR F101, F102 AND FHP SERIES FILTER HOUSING - ALL GRADES)
TABLE 1 BOTTOM BLIND FLANGE WEIGHTS
(F101 Series)
NOTE
Filter models F101-500 thru F101-2000 are equipped
with a single long flange bolt to permit rotating of blind
flange for access to elements.
DO NOT LOOSEN FLANGE BOLTS BEFORE THE
VESSEL IS COMPLETELY DEPRESSURIZED.
WARNING
On units with manual drain valve, stand clear and turn manual
valve until fully open. Leave valve open until all pressure is out
of filter housing and bottom blind flange is removed. On units
with automatic drain valves (timed electric type) allow valve to
cycle until all pressure is out of filter housing.
Provide support under blind flange to prevent it from falling
when bolts are removed.
Remove bolts from flange and lower blind flange for access to
elements.
Remove hex fastener from tie rod and remove used element
from housing. Discard used element properly.
2.
ENDCAP COLOR
Black
Green
Red
Blue
Zinc Plate
Black
GRADE
AA
A
B
C
DESCRIPTION
Extra Coarse Coalescing
Coarse Coalescing
General Purpose Coalescing
High Efficiency Coalescing
ENDCAP COLOR
Black
Green
Red
Blue
GRADE
RAA
RA
RB
RC
HT
RD
DESCRIPTION
Extra Coarse Particulate
Coarse Particulate
General Purpose Particulate
High Efficiency Particulate
High Temperature Particulate
Vapor Adsorbing
®
WARNING
BLIND FLANGES ARE HEAVY AND COULD CAUSE IN-
JURY IF ALLOWED TO FALL. SEE (TABLE 1) FOR BLIND
FLANGE WEIGHTS.
3.
4.
5.
Page view 0
1 2 3 4

Summary of Contents

Page 1 - F101 SERIES

PRINTED IN THE USA © 2000 VAN AIR SYSTEMS INC. 2950 MECHANIC STREET, LAKE CITY, PA 16423 PAGE 1FILTERMODELF101-500F101-1000F101-1500F101-2000F101-350

Page 2 - F102 SERIES

PAGE 2 © 2000 VAN AIR SYSTEMS INC. 2950 MECHANIC STREET, LAKE CITY, PA 16423 PRINTED IN THE USAsmall o-ring in groove on hex fastener. Be sure that l

Page 3 - FHP-670-7.25

PRINTED IN THE USA © 2000 VAN AIR SYSTEMS INC. 2950 MECHANIC STREET, LAKE CITY, PA 16423 PAGE 3FIGURE 3 TYPICAL ASSEMBLY (F102 Series)*Insert appro

Page 4 - WARRANTY

PAGE 4 © 2000 VAN AIR SYSTEMS INC. 2950 MECHANIC STREET, LAKE CITY, PA 16423 PRINTED IN THE USAMAKING COMPRESSED AIR AND GAS WORK BETTER SINCE 1944.2

Related models: E101 Elements

Comments to this Manuals

No comments