WARNINGS
Max Pressure 300 PSIG
PRODUCT PURPOSE & FUNCTION:
Van Air's PD-5 Differential Pressure Indicators provide a visual indication for element
changeout. Designed for F200-55-1/2 thru F200-1000-3 filters, the PD-5 indicator needle will point to
red when a pressure drop of 10 PSID has occurred.
DO NOT INSTALL PD-5 TO EQUIPMENT WHILE UNDER PRESSURE.
FOLLOW INSTRUCTIONS FOR PD-5 WHEN INSTALLING INTO AIR SYSTEM.
DO NOT OPERATE UNIT ABOVE 300 PSIG.
A ZERO DIFFERENTIAL PRESSURE DOES NOT MEAN THAT THE FILTER IS
DEPRESSURIZED. NEVER REMOVE THE INDICATOR AND/OR FILTER
BOWL WITHOUT DEPRESSURIZING THE FILTER HOUSING AND ADJA-
CENT PIPING. FAILURE TO DO SO MAY RESULT IN SERIOUS PERSONAL
INJURY AND/OR DAMAGE TO THE FILTER HOUSING AND/OR INDICATOR.
FIGURE 1 PD-5 KIT DETAILS
INSTALLATION INSTRUCTIONS
PD-5
DIFFERENTIAL PRESSURE INDICATOR KIT
P/N: 84-10001
PD-5
BLANKING
PLATE
O-RING
MOUNTING
SCREWS
DUST
CAP
RED
GREEN
INDICATOR
O-RING
SPECIFICATIONS
MAXIMUM WORKING PRESSURE 300 PSIG
MAXIMUM TEMPERATURE 225°F
MATERIAL
BODY NYLON 6
LENSES POLYCARBONATE
SEALS (O-RINGS) BUNA-NITRILE
MAGNETS ANISOTROPIC
FERRITE
WEIGHT 3.4 OZ
PRINTED IN THE USA ©2000 VAN AIR SYSTEMS INC.
APRIL 2000
P/N: 432-10001
Page view 0